Web Orders Over $100 Ship Free. Enter Promo Code "SHIPFREE" for free UPS Ground Shipping at Checkout. (USA Only)

TI-CMXDLP-C Combination Coating & Wall Thickness Gauge kit with Color LCD and T-102-2900 probe

Click images to enlarge.
2 Versions:
TI-CMXDLP - Black & white model
TI-CMXDLP-C - Color model

The new CHECKLINE® TI-CMXDLP is the top-of-the-line model in the CMX Series of Gauges that measures both coating and wall thickness quickly and accurately—from only one side. In addition, when switched to Pulse-Echo mode, the TI-CMXDLP automatically measures and eliminates the coating from the wall thickness measurement, enabling the user to locate the finest corrosion and pitting—without removing the coating.

It features an A-Scan Display Mode allowing the user to see the actual wave form echoes, graphically, providing the insight necessary to tune the settings on the gauge for optimal performance. This is especially important on challenging measurement tasks. The TI-CMXDLP also features a new E-EV Operating Mode ("Echo-Echo-Verify"), also known as Triple-Echo Mode, which provides addition assurance that the displayed measurement is accurate and fully verified by subsequent echoes.

Oversized graphic LCD is backlit and features easy to read fonts, graphics and display codes showing all critical settings including Velocity, Operating Mode, Alarms, Scan Mode and more. The backlight can be set to ON (always-on), OFF (always-off) or AUTO (automatically-on when measuring).

Try the TI-CMXDLP yourself!
Click here for our TI-CMXDLP Demo

Five user-selected operating modes are included:

Coating On: Measures wall thickness using Pulse-Echo. It separately displays wall & coating thickness.

Coating Off: Measures wall thickness using Pulse-Echo. It displays wall thickness only.

Temperature Compensated: Measures wall thickness using Pulse-Echo and automatically adjusts calibration to compensate for changes in material temperature.

Thru-Coat: Measures wall thickness only using Echo-Echo. (coating is NOT included)

Coating Only Mode (CT): (Coating Thickness) Measures from 0.0005 to 0.100 inches (0.013 to 2.540 mm). Range will vary slightly depending on the coating.

New Features in Version 2.0

  • Built-in Memory, 4GB Capacity
  • Data transfer to PC via USB output
  • Stored data in "Grid" or "Sequential file with date & time stamp
  • High speed scan 200Hz
  • TDG (Time Dependent Gain)
  • Quick screen capture to (.tif) file
  • Improved linearity tables (in all measurement modes)
  • 110dB gain range
  • Setups can be backed up or restored using USB connection
  • Display update rate (25Hz)
  • PRF (pulse repetition frequency 250Hz)
  • Line power available using USB-C to PC or standard power adapter
  • Display rotation (portrait/landscape) – color version only
  • Display update rate (25Hz black & white, 60Hz color)

Features

  • NIST Traceable Calibration Certificate Included
  • Wide variety of Probes, both DUAL-ELEMENT and SINGLE-ELEMENT can be used for nearly any application.
  • Auto probe recognition with Auto Zero or Manual Zero.
  • Bar graph with user-set start end values providing highest resolution around the target thickness value.
  • Differential Mode allows user to set a "target thickness value" and display will show the DIFFERENCE between actual and target thickness as a plus or minus value.
  • 64 custom setups can be stored and retrieved for convenient use and labeled for easy identification
  • Display Hi/Lo Alarm Limits with audible and visual indicators.
  • Adjustable Gain in 5 steps (VLow, Low, Med, Hi & VHi) in 2db increments providing a 8 db gain adjust range (42–50 db).
  • Measures Coatings up to 0.100"
  • Metal housing provides strong protection against harsh environments.
  • T-8071-0868 Probe to 1"-1MHz Single-Element Membrane Probe to measure Blow Holes in Thick PE Pipes and Fittings
  • IP 65 Rated
  • CE Certified
  • Warranty: Gauge: 2 Years Probes: 90 Days
  • Made in USA

Special Features of TI-CMXDLP Data-Logger

  • Built-in memory with RS-232 output for transferring data to a Printer or PC

  • Includes Datacomm Data Transfer & Analysis Software and RS-232 Cable, FREE

  • Data Files can be user-set for a "grid type" structure where data is formatted in Rows & Columns or a "sequential" file where all data appears in a single column

  • Each "grid type" File can be set for up to 999 rows by 52 columns

  • Each "sequential" File can be set for up to 512 rows by 1 column

  • Each File can be set for "data only" or as "data plus B-scan Graphic". Memory Capacity is over 225,000 data values or over 16,000 data values with B-scan

High Speed Scan Mode & B-Scan Mode

Hi-Speed Scan Mode B-Scan Mode
High Speed Scan Mode B-Scan Mode
Scan Mode measures 64 times per second, displaying the max and min reading measured during the scan interval. Sample rate is 200/sec when coating measurement is off. The B-Scan displays a time based cross section view of test material of the contour of the blind, or underside of a pipe or tank application. the B-Scan view draws at a rate of seven seconds per screen from right to left.

Related Products

A-149-6002 rubber shell thickness gauge
Click image for more info
Protective Rubber Boot for TI / ZX Series Tall Body Ultrasonic Thickness Gauges
TICC-MVX Protective Holder for Ultrasonic Gauges - F-149-0001
Click image for more info
Protective Holder for Ultrasonic Gauges
- Constructed from heavy duty Cordura Nylon
- Includes wrist & shoulder straps
Certified Steel Test Blocks
Click image for more info
Certified Steel Test Blocks
- Includes NIST Traceable Calibration Certificate
- Precision Machined and Finished
- Includes PLASTIC Storage Box
SB4 & SB6 Uncertified Steel Test Blocks
Click image for more info
Ultrasonic Test Blocks without certification
- Fabricated from 1018 Steel or 304 Stainless Steel
- ISO Calibration OPTIONAL
CF12 Sound Safe Ultrasonic Couplant
Click image for more info
Coupling Fluid
- Temp Range: 0 - 200 °F, -18 - 93 °C
Click image for more info
High Temperature Coupling Fluid
- Temperature Range:
0° to 600° F
-18° to 315° C
- Supplied in 2oz tube
High Temperature Coupling Fluid - CF-4H-950F
Click image for more info
High Temperature Coupling Fluid
- Temperature Range: 600° to 950° F (316° to 510° C)
- Very slow drying; allows for long-term coupling without reapplication
ultrasonic trandsducer holder v-block
Click image for more info
Ultrasonic Transducer Holder
Click image for more info
Data-Logging Ultrasonic Coating & Wall Thickness Gauge
- Adjustable Gain in 5 steps (VLow, Low, Med, Hi & VHi) in 2db increments providing a 8 db gain adjust range (42–50 db).
Click image for more info
Software for Thickness Gauges

Complete Kit

The TI-CMXDLP is supplied as a complete kit with the gauge, probe, 4 oz. bottle of coupling fluid, 2 AA batteries, NIST-Traceable Calibration Certificate, operating manual, Software, RS-232 output cable, RS-232 to USB adapter, software all in a foam-fitted carrying case.

Measuring Limits

Minimum Radius for Convex Surfaces 0.350" (8.89 mm)
Minimum Radius for Concave Surfaces 3" (76.2 mm)
Minimum Headroom 1" (25.0 mm)
Minimum Sample Diameter 0.150" (3.8 mm)
Minimum Substrate Thickness - F NA
Minimum Substrate Thickness - NFe NA

TI-CMXDLP-C Color Model

Oversized graphic color LCD is backlit and features easy to read fonts, graphics and display codes showing all critical settings including Velocity, Operating Mode, Alarms, Scan Mode and more. The backlight can be set to ON (always-on), OFF (always-off) or AUTO (automatically-on when measuring).
With ultra hi-speed processing (display update refresh of 120 times/second), TI-CMXDLP-C is also extremely effective tool when used in the Flaw "Prove-up" Mode, simulating the function of a Flaw Detector at a fraction of the cost to identify and locate cracks, dis-bonds, weld defects, etc. Also includes a "dampening feature" which helps filter the raw waveform data to clean-up the signal, especially with very low and very high frequency probes.

Quick Change Shear Wave Transducers(QC)

Description: Threaded shear wave transducers for quickly interchanging between wedges. Ideal for limited access and curved surfaces.
Used: General weld inspection
Damping: High gain (G), Resolution(R) *Specify damping after (QC), No damping on 3.5 MHz
Connectors: Microdot
Element Size 2.25 MHz 3.5 MHz 5.0 MHz 10.0 MHz
.250" dia. QC2525 - QC2550 QC2510
.375" dia. QC3725 - QC3750 QC3710
.500" dia. QC5025 PQC5035 QC5050 QC5010

Standard Quick Change Wedges (QW)

Quick Change Wedges - Custom angles available on request
Element Size .250" DIA. .375" DIA. .500" DIA.
45° QW2545 QW3745 QW5045
60° QW2560 QW3760 QW5060
70° QW2570 QW3770 QW5070

Specifications

Range in Steel:Pulse-Echo Mode: Pit and Flaw detection measures from 0.025 - 9.999inches (0.63 to 254 millimeters)

Echo-Echo Mode: Thru Paint & coatings measures from 0.100 - 4.000 inches (2.54 to 102 mm). Range will vary depending on the thick
Range in Coating Only Mode0.0005" - 0.1000" / Resolution: 0.0001"
(0.013 - 2.540 mm / Resolution: 0.001 mm)
Max Coating0.100"
Resolution:.001 inches (0.01mm)
Velocity Range:.0492 to .3936 in./ms
1250 to 9999 meters/sec
Units:Inch or mm
Measurement Modes:- Pulse-Echo (corrosion mode)
- Pulse-Echo Coating (Corrosion w/o coating)
- Echo-Echo (thru-paint)
- Temp Comp (auto adjust for material temp)
- Coating Only (Ultrasonic Coating Gauge)
Transducer Types:Dual Element (1 to 10 MHz).
OutputRS-232 for upload/download of setups
Memory capacity:TI-CMXDLP: over 200,000 measurements
Power Source:Three 1.5V alkaline or 1.2V NiCad AA cells
Battery Life:Typically operates for 150 hours on alkaline and 100 hours on NiCad
Auto Power off:After 5 minutes of non-use
Display:1/8 in. VGA grayscale display 62 x 45.7mm
Keyboard:Membrane switch with twelve tactile keys
Case:Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed).
Temp. LimitsAmbient: -20 to 120° F (-30 to 50° C)
Material: -0 to 200° F (-20 to 100° C
Special high temperature probes are optionally available.
Weight, net:383 grams
Dimensions:63.5 W x 165 H x 31.5 D mm
Warranty:2 year limited
Certification:CE Approved, Factory calibration traceable to national standards

Downloads

Buy Now

Item Description Price
TI-CMXDLP-C
Combination Coating & Wall Thickness Gauge kit with Color LCD and T-102-2900 probe
$3,675.00
Accessories
1/4" diameter, 5.0 MHz, dual element, through-coating transducer, Side In, Potted
$360.00
1/2" diameter, 5.0 MHz dual element transducer, coating thickness capabable, Side in, Potted
$375.00
1/2" diameter, 3.5 MHz Coating Transducer
$375.00
T-102-2900-H
1/4" 5Mhz Coating Transducer for Material Temp up to 300 °F (150 °C)
$385.00
1/4" diameter, 5.0 MHz dual element transducer Hi-Temp (900 F/500 C) Top in, Microdot
$470.00
1/2" 5 Mhz Hi Damp Coating Probe with 50 ft. underwater cable
$705.00
Protective Holder for Long Body UT Gauges, F-149-0001
$85.00
SoundSafe Coupling Fluid - 12 oz / 354 ml - NSN: 6635-01-553-0559
$30.00
Sono 600 High Temp Coupling Fluid 4 oz / 118 ml (0 - 700 F / -18 to 371 C)
$78.00
High Temp Coupling Fluid 4oz (600 - 780 F / 316 - 404 C)
$150.00
V-Block Transducer Holder (For 3/16" & 1/4" Transducers only), F-000-7001
$170.00
QC2525
Shear Wave Transducer 2.25 Mhz .250" Dia
$275.00
QC3725
Shear Wave Transducer 2.25 Mhz .375" Dia
$275.00
QC5025
Shear Wave Transducer 2.25 Mhz .500" Dia
$275.00
PQC5035
Shear Wave Transducer 3.5 Mhz .500" Dia
$325.00
QC2550
Shear Wave Transducer 5.0 Mhz .250" Dia
$275.00
QC3750
Shear Wave Transducer 5.0 Mhz .375" Dia
$275.00
QC5050
Shear Wave Transducer 5.0 Mhz .500" Dia
$275.00
QC2510
Shear Wave Transducer 10.0 Mhz .250" Dia
$300.00
QC3710
Shear Wave Transducer 10.0 Mhz .375" Dia
$300.00
QC5010
Shear Wave Transducer 10.0 Mhz .500" Dia
$300.00
LEMO 00 - Microdot Single Probe Transducer Cable, 4 foot length
$80.00
QW2545-DNU
Use p/n X-004-0038
$0.00
QW2560-DNU
Use p/n X-004-0039
$0.00
QW2570-DNU
Use p/n x-004-0040
$0.00
QW3745-DNU
Use p/n X-004-0041
$0.00
QW3760-DNU
Use p/n X-004-0042
$0.00
QW3770-DNU
Use p/n X-004-0043
$0.00
QW5045-DNU
Use p/n X-004-0044
$0.00
QW5060-DNU
Use p/n x-004-0045
$0.00
QW5070-DNU
Use p/n X-004-0046
$0.00
1.00", 1.00 Mhz, Side, BNC, Composite Single-Element Membrane Probe
$505.00
BNC - LEMO 00 Single Probe Transducer Cable, 6 foot length
$80.00
BATT-RC4AA-WC
4-pack AA Ni-MH Rechargeable Batteries & Charger Kit
$35.00
Protective Rubber Boot for Tall Format Ultrasonic Thickness Gauges
$115.00
In stock
1 Week Lead Time (Estimated)
2-3 Week Lead Time (Estimated)
Lead Time Varies, Please contact us for availability.
Unavailable