The PD765 Digital Indicator is designed to work with Checkine tension sensors providing a large, bright LED display of real-time tension values. It is easy to set up and permits flush panel mounting in a 1/8 DIN cutout. The PD765-6R3-20 offers 4-20 mA output for external recording and data-logging purposes. Hi/Lo limits and relay contacts can be optionally specified on PD765-6R5-10 supplied instead of the 4-20 mA analog output. The standard model PD765-6R3-20, operates from all worldwide AC-Power (85-265V AC). 0-10V DC output is not available.

Features

  • Can be scaled to any engineering units desired with user-set decimal point.
  • 4-20 mA analog output for recording and control purpose (No analog output provided on PD765-6R5-10)
  • Requires 85-265V AC Power, provides regulated power for the tension sensor
  • Hi/Lo Limits and relay contacts provided on PD765-6R5-10 (supplied instead of 4-20ma output)
  • User-set filters can be used to adjust signal sensitivity to reduce fluctuations of tension values

Ordering Guide

PD765-6R3-20 - Digital Tension Indicator 4-Digit Display for connection to tension Sensors. Provides regulated power for the sensor, includes 4-20mA Analog output. Requires 85-265V AC-Power

PD765-6R5-10 - Digital Tension Indicator 4-Digit Display for connection to tension Sensors. Provides regulated power for the sensor, includes 2 Alarm Limits & Relays. No analog output provided. Requires 85-265V AC-Power

PD6000-6R3 Digital Tension Indicator 4-Digit Display for connection to tension Sensors. Provides regulated power for the sensor, includes 4-20mA Analog output. Requires 85-265V AC-Power

Dimensions

Specifications

General Specifications
Display Range-1999 to 9999
Display4-digit Red LED, 14.2 mm high
Display IntensityEight user selectable levels
Front PanelNEMA 4X, IP65; panel gasket provided
Programming MethodsFour front panel buttons, cloning with Copy feature, PC with MeterView or LavVIEW software and Modbus registers. Certified LabVIEW driver available.
Noise FilterProgrammable 2 to 199 (0 will disable filter)
Display Update RateProcess/RTD: 3.7-5/sec; TC: 1.8-2.5/sec
OverrangeDisplay flashes 9999
UnderrangeDisplay flashes -1999
RecalibrationAll inputs are calibrated at the factory; recalibration is recommended at least every 12 months.
Min/Max DisplayStored until reset by user or meter is turned off
PasswordRestricts modification of programmed settings
Non-Volatile MemorySettings stored for a minimum of 10 years
Power Options85-265 VAC; 12-36 VDC
Required FuseUL Recognized, 5 A max, slow-blow; up to 6 meters may share one fuse
Normal Mode Rejection64 dB at 50/60 Hz
Isolation4 kV input/output-to-power line; 500 V input-to-output or output-to-24 VDC supplies. -6R5 models only: 100 V output-to-24 VDC supply
Operating Temperature0 to 65°C
Storage Temperature-40 to 85°C
Relative Humidity0 to 90% non-condensing
ConnectionsPower & Signal: removable screw terminal blocks accept 12 to 22 AWG. Serial: RJ11 header, standard on all meters
Enclosure1/8 DIN, high impact plastic, 94 V-0, color: gray
Weight9.5 oz (269 g) (including options)
Warranty3 years
Accuracy±0.05% FS ±1 count; square root: ±0.1% FS ±2 counts
FunctionLinear or square root
Low-Flow Cutoff0 to 9999 (0 disables cutoff function)
Decimal PointUp to 3 decimals
CalibrationScale without signal or calibrate with signal source
Calibration RangeUser programmable over entire range of meter
Input InpedanceVoltage range: greate than 1MΩ, Current range: 50-100 Ω, varies with resettable fuse impedance
Input OverloadProtected by automatically resettable fuse
Temperate Drift±50 PPM/°C
Transmitter SupplyIsolated, one or two transmitter supplies:
P1: 24 VDC ±10% @ 200 mA max (-10 option)
P1 & P2: 24 VDC ±10% @ 200 mA & 40 mA max (-20 option)
Relays (Model PD765-6R5-10 only)
RatingForm C (SPDT); rated 3 A @ 30 VDC or 3 A @ 250 VAC resistive load; 1/14 HP (≈50 watts) @ 125/250 VAC for inductive loads such as contactors, solenoids, etc.
Deadband0 - 100% FS, user selectable
High or Low AlarmUser may program any alarm for high or low
Relay Operation1. Automatic (non-latching)
2. Latching
3. Pump alternation control
Relay ResetUser selectable via front panel buttons or PC
1, Automatic reset only (non-latching)
2. Automatic plus manual reset at any time (non-latching)
3. Manual reset only, at any time (latching)
4. Manual reset only after alarm condition has cleared (latching)
Automatic ResetRelays reset when input passes the reset point
Manual ResetFront panel button, MeterView, Modbus registers
Time Delay0 to 199 seconds, on and off delays; programmable
Fail-Safe OperationProgrammable, independent for each relay. Relay coils are energized in non-alarm condition. In case of power failure, relays will go to alarm state.
Auto InitializationWhen power is applied to the meter, relays will reflect the state of the input to the meter
Isolated 4-20 mA Transmitter Output
Scaling Range1.00 to 23.00 mA; reverse scaling allowed
CalibrationFactory calibrated 4.00 to 20.00 mA
Accuracy±0.1% FS ±0.004 mA
Temperature Drift50 PPM/°C Note: Analog output drift is separate from input drift
Isolation500 V input-to-output or output-to-24 VDC supplies; 4 kV output-to-power line
Output Loop Resistance24 VDC: Minimum - 10Ω Maximum - 700Ω
35 VDC (external): Minimum - 100Ω Maximum - 1200Ω
Virtual Meterhttp://www.predig.com/tvm/index.php

Downloads

Buy Now

Item Description Price
PD765-6R3-20
Digital Tension Indicator 4-Digit Display Panel-Mounted - AC Powered
$508.00
In stock
1 Week Lead Time (Estimated)
2-3 Week Lead Time (Estimated)
Lead Time Varies, Please contact us for availability.
Unavailable