The included digital indicator can display torque in lb-ft, N-m, Lb-in or Kg-m (selectable) with an accuracy of +/-1% (bi-directional with optional reverse threaded run-down-fixture).
The TT-41000 Series impact torque testers are designed to check tool operation and consistency. The measured torque value does not precisely indicate the effective clamp load of the bolt. It is common for tool manufacturer's specified torque output to vary by +/-20% versus what the TT-41000 will indicate however the critical value is repeatability, not measured output.
The TT-IMP is designed for use with impact and impulse tools only. It is not compatible with hand torque wrenches or reaction tools. The display included with the TT-IMP can be used with our IT Transducers to extend its capabilities.
- Counts Pulses / Blows while displaying peak torque
- Heavy Duty Construction
- Solid machined aluminum plate for weight reduction and long term durability
- Spline engagement of rundown into torque transducer improves durability of transducer
- Test stand is designed with feet to accomodate bolting test stand to bench
- Supplied as a complete system with bench-mount transducer, run-down-fixture, display and connecting cable.
Model | Calibrated Measuring Range | Drive Size |
---|---|---|
TT-410250F-IMP | 25 - 250 lb-ft / 34 - 340 Nm | |
TT-410500F-IMP | 50 - 500 lb-ft / 68 - 680 Nm | |
TT-4101000F-IMP | 100 - 1000 lb-ft / 135 - 1355 Nm | |
TT-4102000F-IMP | 200 - 2000 lb-ft / 270 - 2700 Nm | 1.5" Female Square |
TT-4102500F-IMP | 250 - 2500 lb-ft / 340 - 3400 Nm | 1.5" Female Square |
TT-4105000F-IMP | 500 - 5000 lb-ft / 680 - 6800 Nm | 1.5" Female Square |
TT-4107500F-IMP | 750 - 7500 lb-ft / 1017 - 10170 Nm | 1.5" Female Square |
Back off run-down between each test
Be aware of heat build-up, it breaks down the lubricant in the run-down fixture, increasing friction. Let the run-down cool after a few minutes of use (this will vary by torque range)
Calibrated Range | 10-100% Full Scale, bi-directional (with optional reverse threaded run-down-fixture). |
Accuracy | ±1.0% of indicated (within calibrated range) |
Warranty | 1 Year |
Calibration Certificate | Includes NIST Traceable calibration certificate with data |
Operating Temp | 32 - 120 °F (0-50 °C) |
Power | Rechargable NiMH batteries provide 10 -12 hours of continuous use |
Weight | 10-20lbs depending on range |
Specifications below for Display | |
Operating Modes | Peak, 1st Peak, Track |
Resolution | 4 Active Digits |
Filtering | Selectable; 125Hz, 250Hz, 500Hz, 1000Hz, 1500Hz and 2000Hz |
Memory | data storage of up to 999 readings |
Data Output | RS-232 |
Display | 62 x 62mm backlit LCD |
Alarm Limits | LED for Visual Alarm Limits |