TS621HD High Speed Strain Gauge Amplifier

TS621HD High Speed Strain Gauge Amplifier
Click images to enlarge.
The TS621HD electronic strain gauge amplifier is especially intended for amplification of high frequency sensor signals in mV range.

Best temperature and long-term stability as well as high accuracy are guaranteed by using modern technology.

The TS621HD delivers superb performance features such as galvanic isolation, removable terminal block for the sensor connections, multiple options and high quality.

Features

  • Detection of high frequency sensor signals by wide gain bandwidth; DC to 40kHz
  • Low noise
  • Great noise immunity and service reliability for use in rough industrial operation
  • Input power supply of 24V DC, reverse-polarity protected, providing:
    • wide operating input power supply of 19-36V DC, LED indicates power-on status
    • integrated DC-DC converter for galvanic isolation between power supply and measuring circuit (very important to avoid ground loops in combination with secondary electronics)
  • Provides a well-regulated power supply for sensor excitation, balanced to ground
  • Coarse and fine adjustments for zero and amplification setting
  • Screw terminal for power and outputs
  • Removable screw terminal plug for the sensor connections

Applications

  • shock or impact testing
  • load test on crash-tests with dummies, seatbelt materials etc.
  • analyzing shock waves in hydraulic systems
  • vibration analysis
  • dynamic testing of materials
  • high dynamic stress measurements on materials and constructional elements

Standard Output

Voltage output Vout (@ Gnom • Usig)
0 to ± 10 V, bipolar, max. 10 mA

Optional Outputs

In standard version the strain gauge amplifier TS621HD offers a voltage output.
The device can be extended by one additional output.
Option D 2nd voltage output, filtered for TS621 / TS621HD
click image for more info
Option D
2nd voltage output, filtered
  • 0 to ±10V
  • Selectable cut-off frequency
  • 0.5 - 5 - 10 - 20 Hz
  • Setting by DIP-switches
click here to view more information
2nd voltage output with additional amplification (40kHz)
click image for more info
Option X40
2nd voltage output with additional amplification (40kHz)
  • 0 to ±10V
  • Additional amplification, selectable 2x, 3x, 4x or 5x
  • Filtered (cut-off-frequency 40Khz)
  • Setting by DIP-switches
Option DX 2nd voltage output, filtered with additional amplification for TS621 / TS621HD
click image for more info
Option DX
2nd voltage output, filtered with additional amplification
  • Additional amplification, selectable 2x, 3x, 4x or 5x
  • Cut-off frequency 0.5 / 5 / 10 / 20 Hz
  • Setting by DIP-switches
click here to view more information
Current output 0/4-20mA (40kHz)
click image for more info
Option A40
Current output 0/4-20mA (40kHz)
  • Parallel to voltage output Vout
  • Bipolar 0 to ±20mA
  • Unipolar 0 to +20mA
  • Unipolar 4 to +20mA
  • Filtered (cut-off-frequency 40Khz)
  • Setting by DIP-switches
Option AD
click image for more info
Option AD
Current output 0/4-20mA, filtered
  • Bipolar 0 to ±20mA
  • Unipolar 0 to +20mA
  • Unipolar 4 to +20mA
  • Cut-off frequency 0.5 / 5 / 10 / 20 Hz
  • Setting by DIP-switches
click here to view more information

Specifications

DesignDIN-rail housing for convenient snap-in installation
Accuracy class0.1
Sensors to be connected:
- strain gauge, full bridge
admissible connection impedance
≥ 150 Ω
Bridge excitation voltage
- referenced to ground (GND)
10 ± 0.5% V DC
± 5 V DC
Nominal gain Gnom667
Nominal measuring range Usig± 15 mV
Calibration range referenced to Gnom38% to 100% to 580%
Adjustment range zero @ Gnomfine approx. ± 20% of final value
coarse approx. ± 60% of final value
Input impedance1010 Ω
Cut-off frequency (- 3 dB)approx. 40 kHz
Phase delay (frequency range)< 7.5 µs
max. slew rate Vout2.5 V / µs
max. ringing at surge [2]< 5%
Standard OutputVoltage output Vout (@ Gnom • Usig): 0 to ± 10 V, max. 10 mA
Nominal temperature range0 to 60°C (32 to 140°F)
Operation temperature range0 to 60°C (32 to 140°F)
Storage temperature range-25 to 75°C (-13 to 167°F)
Temperature influence per 10°C
- on zero at amplifier output
- on calibration

< 10 mV (@ Gnom)
< 0.05% of final value
Supply voltage19 to 36 V DC
Power consumptionmax. 3 W
integrated DC-DC converter for galvanic isolation between supply voltage and measurement circuit
Amplifier connectionscrew terminals for flexible cable 0.2 to 2.5 mm2
Sensor connectionplug with screw terminals for flexible cable 0.08 to 1.5 mm2
Dimensions (L x W x H)80mm x 25mm x 95mm (3.15" x 0.98" x 3.74")
Weightapprox. 100g (0.22 lbs)
[2] @ Gnom and 15 mV square wave amplitude input signal (Usig)

fC = Cut-off frequency
Vout = Voltage at standard output
Gnom = Nominal gain
Vout* = Voltage at optional output with select. amplification factor
Usig = Input voltage
Vdout = Voltage at optional damped output

Downloads

Related Products

Click image for more info
Strain Gauge Amplifier
- Designed for use with a wide range of strain-gauge-based force, load and tension sensors
- 0-10VDC analog output
Click image for more info
Miniature Measuring Amplifier for Strain Gauge Sensors
- voltage output 0 to ±10V; optional current output 0-20mA or 4-20mA
- input power supply of 24V DC, reverse-polarity protected
Click image for more info
Digital Tension Indicator
- Selectable “damping function” reduces display fluctuations
- 24V DC power supply with galvanic isolation
Click image for more info
Tension Indicator/Amplifier Console
- 1 to 4 measuring channels
- For 24V DC power supply
- Rugged industrial design in steel plate-housing
Click image for more info
Data Transfer & Analysis Program For Honigmann Tension Sensors
- Real time display of measured values graphically and digitally, indicating the actual value in tension units
- Export data in ASCII format