4 Tension Ranges from 1000 g up to 10 Kg
4 Roller Widths; 7, 10, 15, 20 mm
Can be supplied with V-Grooved or U-Grooved Rollers, TSC-Series
Built-in signal conditioning with ZERO and SPAN pots provide a high-level, analog output to minimize the chance for signal interference.
It can be used for process diagnostics for continuous monitoring and recording online tensions. The MZB1 Tension Sensor can also be used as part of a closed-loop control system with 3rd-Party controller.
Mounting possibilities: The MZB1 Sensor can be mounted on a flat plate using the threaded holes on the underside of the housing, through holes using the flange at each end of the housing, or using the holes in the front plate.
- Strain Gauge-based sensor provides accuracy of 1.5% Full Scale or better.
- Compact housing for convenient parallel mounting when access space is limited
- Easy calibration using the zero and gain adjustment pots located on the side of the housing
- Built-in amplifier provides a 0-1V DC output as standard (0-10V or 4-20mA, optional)
- Can be used together with SC-PM Digital Tension Indicator or with user-supplied electronics
- Various Digital Output Signals available, inquire
- Flat Cylindrical Rollers are fabricated from Hardcoat Anodized Aluminum
- Rollers width of 7, 10, 15, 20 mm are available
- Connection cables are offered in 2-meter, 5-meter and custom lengths
Model | Tension range | Measuring Head Width* | Roller Width |
---|---|---|---|
MZB1-1000 | 0 – 1000 g/cN | 7, 10, 15, 20 mm | |
MZB1-2000 | 0 – 2000 g/cN | 7, 10, 15, 20 mm | |
MZB1-5000 | 0 – 5000 g/cN | 7, 10, 15, 20 mm | |
MZB1-10K | 0 – 10 Kg / daN | 7, 10, 15, 20 mm |
Other measuring units available, such as g or kg.
* Outer dimensions of front plate
Accuracy | ±1.5 % full scale and ±1 digit % full scale or better Other calibration material ±3 % full scale or better |
Overload protection | 100 % of tension range |
Measuring principle | Strain gauge bridge |
Measuring roller deflection | Max. 0.5 mm |
Natural frequency | Approx. 500 Hz, depending on tension range |
Output signal | Standard: 0 – 1 V DC (analog) impedance: ≥ 5 kΩ Option: 0 – 10 V DC (analog), 4 – 20 mA DC (current) Option digital: USB, RS-232 or RS-422 |
Damping (fg) | Standard: 30 Hz (other values on request) |
Temperature range | 10 – 45 ºC |
Humidity | 85 % RH, max. |
Power supply | +15…24 V DC, max. 21 mA (standard output) Code A3: 50 mA, Code 422: 50 mA, Code 232: 40 mA |
Housing material | Aluminium |
Weight, net (gross): | Approx. 420 g (580 g) |