Gage Models: |
F1, F2, F3 |
N1, N2, N3 |
FN1, FN2, FN3 |
FT1, FT2, FT3 |
Range: |
0 - 60 mils | 0 -250 mils | ||
0 - 1500 um | 0 - 6 mm | |||
Accuracy*: |
+ (0.05 mils + 1%) 0 - 2 mils + (0.1 mils + 1%) > 2 mils |
+ (0.5 mils + 1%) 0 - 100 mils + (0.5 mil + 3%) > 100 mils |
||
+ (1 um + 1%) 0 - 50 um + (2 um + 1%) > 50 um |
+ (0.01 mm + 1%) 0 - 2.5 mm |
|||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
![]() |
|||||
Probe Models: |
FS |
NS |
FNS |
NAS |
FTS |
Range: |
0 - 60 mils | 0 -25 mils | 0 -250 mils | ||
0 - 1500 um | 0 - 625 um | 0 - 6 mm | |||
Accuracy*: |
+ (0.05 mils + 1%) 0 - 2 mils + (0.1 mils + 1%) > 2 mils |
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
+ (0.5 mils + 1%) 0 - 100 mils + (0.5 mil + 3%) > 100 mils |
||
+ (1 um + 1%) 0 - 50 um + (2 um + 1%) > 50 um |
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
+ (0.01 mm + 1%) 0 - 2.5 mm |
|||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
![]() |
|||
Probe Models: |
FRS |
NRS |
FNRS |
Range: |
0 - 60 mils | ||
0 - 1500 um | |||
Accuracy*: |
+ (0.05 mils + 1%) 0 - 2 mils + (0.1 mils + 1%) > 2 mils |
||
+ (1 um + 1%) 0 - 50 um + (2 um + 1%) > 50 um |
|||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
Separate Microprobes
![]() ![]() |
||
Probe Models: |
F0S |
N0S
|
Range: |
0 - 25 mils | |
0 - 625 um | ||
Accuracy*: |
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
|
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
![]() |
||
Probe Models: |
F45S |
N45S
|
Range: |
0 - 25 mils | |
0 - 625 um | ||
Accuracy*: |
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
|
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
![]() |
||
Probe Models: |
F90S |
N90S
|
Range: |
0 - 25 mils | |
0 - 625 um | ||
Accuracy*: |
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
|
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
Separate High-Range Probes
![]() |
|||
Probe Models: |
FNTS
|
FKS |
NKS |
Range: |
0 -250 mils | 0 -500 mils | |
0 - 6 mm | 0 - 13 mm | ||
Accuracy*: |
+ (0.5 mils + 1%) 0 - 100 mils + (0.5 mil + 3%) > 100 mils |
+ (1 mils + 3%) 0 - 500 mils + (0.02 mm + 3%) 0 - 13 mm |
|
+ (0.01 mm + 1%) 0 - 2.5 mm |
|||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |