Sample Diameters up to 7.5" (190 mm)
The new CAP-TNP torque meter is a precision instrument that measures OPEN and CLOSE torque values for various applications. As a cap torque analyzer, the CAP-TNP repeatedly determines bottle closure and breakaway torque. It has a wide memory capacity capable of storing 1,000 data points in addition to Average, Maximum and Minimum values. A HI-LO comparator feature can be utilized for a large batch testing to ensure overall product quality.
The CAP-TNP torque meter is USB capable for computer testing. Combined with the free Digitorq Software, additional analysis and testing can be performed.
The CAP-TNP is a portable device powered with internal rechargeable batteries or through an AC Adpater/charger. Designed with a small footprint it can easily be transferred to maximize use around the shop floor or the laboratory.
The CAP-TNP includes free software to analyze your measurement data. The software is Windows 7 compatible and requires Microsoft Excel.
- Includes Traceable Calibration Certificate
- ±0.5% F.S. Accuracy
- Includes Hi/Go/Lo Limits and LED Indicators
- Displays Torque values in, lb-in, Kgcm and Nm, Ncm
- USB interface including FREE Digitorq Software
- Captures Peak Opening, Peak Closing and Average torque values (CCW, CW)
- Three (3) models offered covering small, medium and large sized containers
- One touch operation, retains up to 1000 measurements in memory
- Easy to read L.C.D.
- Rechargeable NIMH batteries and / or Universal AC adapter
- Small foot print, compact, space saver design
-
Open Mode:
Max value when opening
[CCW torque direction] -
Close Mode:
Max value when closing
[CW torque direction] -
Average Mode:
Continuous torque values in real time - CE Certified
- 1 Year Warranty
Model | Capacity | Resolution |
CAP-TNP-0.5 | 0-4.425 Lbf-in 0-0.500 Nm 0-50.00 Ncm 0-5099 gcm |
0.001 Lbf-in 0.001 Nm 0.01 Ncm 1 gcm |
CAP-TNP-2 | 0-17.70 Lbf-in 0-2.000 Nm 0-200.0 Ncm 0-20.39 Kgcm |
0.01 Lbf-in 0.001 Nm 0.1 Ncm 0.01 Kgcm |
CAP-TNP-5 | 0-44.25 Lbf-in 0-5.000 Nm 0-500.0 Ncm 0-50.99 Kgcm |
0.01 Lbf-in 0.001 Nm 0.1 Ncm 0.01 Kgcm |
CAP-TNP-10 | 0-88.5 Lbf-in 0-10.00 Nm 0-1000 Ncm 0-102.0 Kgcm |
0.1 Lbf-in 0.01 Nm 1 Ncm 0.1 Kgcm |
Cap dia. in mm |
Phenolic/ Urea Cap On Glass |
Phenolic/Urea Cap on Plastic |
PP/PE Cap on Glass |
PP/PE Cap on Plastic |
||||
Close Torque | Open Torque | Close Torque | Open Torque | Close Torque | Open Torque | Close Torque | Open Torque | |
15 | 8 | 4 | 6 | 3 | 12 | 7 | 8 | 4 |
18 | 9 | 5 | 7 | 4 | 13 | 8 | 9 | 5 |
20 | 10 | 5 | 8 | 4 | 15 | 9 | 10 | 5 |
22 | 11 | 6 | 9 | 5 | 17 | 10 | 11 | 6 |
24 | 12 | 6 | 10 | 5 | 18 | 11 | 12 | 6 |
28 | 14 | 7 | 12 | 6 | 21 | 12 | 14 | 7 |
33 | 18 | 9 | 15 | 7 | 24 | 14 | 17 | 8 |
38 | 20 | 10 | 17 | 7 | 29 | 17 | 19 | 9 |
43 | 22 | 11 | 18 | 9 | 33 | 20 | 22 | 11 |
48 | 24 | 14 | 20 | 10 | 26 | 22 | 24 | 12 |
58 | 28 | 14 | 24 | 12 | 44 | 26 | 29 | 14 |
70 | 35 | 18 | 28 | 14 | 52 | 32 | 35 | 17 |
89 | 45 | 22 | 36 | 18 | 65 | 40 | 45 | 22 |
100 | 50 | 25 | 40 | 20 | 75 | 38 | 50 | 25 |
Overload protection | 150% |
Sample Diameter Range (min to max) | 0.39" to 7.48" (10 - 190 mm) |
Overload display | Display "OVR" on LCD (blinking on/off) |
Main display | 4-digit LCD display Character height 12mm |
Sub display | 3-digit LCD display Character height 7mm |
Comparator display | Hi, GO, Lo LED Indicators |
Accuracy | ± 0.5% full scale |
Open mode | Max vale when opening. Displays max counter clockwise torque. |
Close mode | Max value when closing. Displays max clockwise torque |
Average mode | Real time display. Displays max torque in real time |
Display Update Time | 1, 2, 4 or 8 updates/second, user-set |
Sampling Rate | 1000 times/second |
Memory data number | 1000 data points (max) |
Statistic process | Average value, max value and min value |
Data output | USB 1.1 / RS232 |
PC software | Digitorque software |
Accessories | USB cable, AC adapter, 30mm chuck pin (4pcs), Manual |
Power | Built in nickle hydride battery or Auto-ranging AC adapter (AC100 - 240V) |
Item Dimensions | 12.60" x 8.94" x 4.96" (320 x 227 x 126mm) |
Shipping Dimensions | 17 x 12 x 6 Inches / 43 x 31 x 16 cm |
Weight | 8 kg (17.62 lbs) CAP-TNP-10: 12.5 kg (27.53 lbs) |
Shipping Weight | 9.5 kg (20 lbs) CAP-TNP-10: 14.5 kg (30 lbs) |
Operation Temperature | 32 - 104°F (0 - 40°C) |
Battery Life | 8 hours after full charge |
Battery Recharge Time | Max. 16 hours |
Battery Type | NiMH |
Country of Origin | China |
Warranty | 2 Years |
Item | Description | Price | ||
---|---|---|---|---|
CAP-TNP-10 | Cap Torque Tester 88 lb-in / 10 Nm Capacity - TNP-10 | $1,147.50 | ||
Accessories | ||||
NISTCAL | NIST Traceable Calibration Certificate with Data for CAP-TNP | $100.00 | ||
TNP-TP30 | Set of 4 standard replacement pegs, 30mm height | $125.00 | ||
TNP-TP50 | Set of 4 extended pegs, 50mm height | $185.00 | ||
Spare / Replacement Power Adapter for most Shimpo gauges | $35.00 | |||
ISO-17025-CT | ISO-17025 Calibration & Certification for Cap Torque Tester | $365.00 | ||
TNP-BATT | Spare / Replacement Battery for CAP-TNP - BFGG0200510 | $100.00 | ||
TNP-CASE | Waterproof, foam-filled carrying case for TNP Torque Testers | $295.00 |